CE-IVD test kits for screening of Leukemia-associated translocations

HemaVision® sensitive and specific tests for detection of leukemia-associated translocations



DNA Diagnostic A/S manufactures a range of HemaVision® diagnostic kits for fast and sensitive screening of chromosome translocations associated with leukemia. The HemaVision® range of tests are fast 12 hours RT-PCR or 4 hours RT-qPCR screening tests, which can detect up to 28 translocations, enabling fast diagnostics and subsequent treatment. The starting material for the HemaVision® tests is total RNA extracted from whole blood or bone marrow. The tests can be performed as a screening for 28 translocations or 7 translocations. Single translocation tests are also available.


There are a total of 17 different kits for detection of chromosomal translocations associated with leukemia. The following CE-IVD test kits are for the screening and detection of 28 translocations in just 4 hours (-28Q), 8 hours (-Screen), or 12 hours (-28N).

  • HemaVision®-28Q
  • HemaVision®-28N
  • HemaVision®-Screen



RT-qPCR Tests for fast and sensitive screening and detection of up to 28 translocations

  • HemaVision®-28Q (Cat. No. HV01-28Q) RT-qPCR HemaVision® kit for the screening and detection of 28 chromosome translocations with more than 145 clinically relevant chromosomal breakpoints in just 4 hours. Supplied in three types of qPCR tubes: WRP, WLP or FRP. Contain material for 12 tests.
  • HemaVision®-7Q (Cat. No. HV01-7Q) RT-qPCR HemaVision® kit for the screening and detection of 7 chromosome translocations with more than 40 clinically relevant chromosomal breakpoints in just 4 hours. These 7 translocations are t(9,22) minor, major,and micro; t(1,19); t(12,21); inv16; t(15,17) S, V and L; t(8,21) and t(4,11). Supplied in tree types of qPCR tubes: WRP, WLP or CRP. Contain material for 12 tests.
  • HemaVision® Q Positive Controls (Cat. No. HV05-PCQ) Positive Controls for HemaVision®-28Q and HemaVision®-7Q . The kit contains HL-60 RNA and in vitro transcribed RNA with a translocation specific sequence. Each of the 5 tubes contains 20 µL RNA with 5x10-17 mol in vitro transcribed RNA. RNA mix contains the following translocations: t(15;17), inv(16), t(8;21), t(12;21), t(1;19), t(4;11), t(9;22), del(1), t(6;9).



Screening for 28 translocations RT-Nested PCR

  • HemaVision®-28N (Cat. No. HV01-28N) Multiplex, nested RT-PCR HemaVision® kit for the screening and detection of 28 chromosomal translocations with more than 145 clinically relevant chromosomal breakpoints in just 12 hours. Contain material for 25 tests (25 master reactions and 15 split- out reactions).
  • HemaVision®-Screen (Cat. No. HV01-Screen) The HemaVision-Screen kit is a supplementary kit to the HemaVision® -28N kit. Multiplex, nested RT-PCR HemaVision® kit for the screening of 28 chromosomal translocations with more than 145 clinically relevant chromosomal breakpoints in just 8 hours. Contain material for 25 tests. (25 master reactions).



Screening for single translocations RT-Nested PCR

  • HemaVision®-5;12N (Cat. No. HV02-512) Nested RT-PCR HemaVision® kit for the detection of the t(5;12)(ETV6-PDGFRB) translocation. Contain material for 25 tests.
  • HemaVision®-8;21N (Cat. No. HV02-821N) Nested RT-PCR HemaVision® kit for the detection of the t(8;21)(RUNX1-RUNX1T1) translocation. Contain marked material for 25 tests.
  • HemaVision®-9;22N (Cat. No. HV02-922N) Nested RT-PCR HemaVision® kit for the detection of the t(9;22)(BCR-ABL1) minor & major translocation. Contain material for 25 tests.
  • HemaVision®-15;17N (Cat. No. HV02-1517N) Nested RT-PCR HemaVision® kit for the detection of the t(15;17)(PML-RARA) translocation. Contain material for 25 tests.
  • HemaVision®-inv16N (Cat. No. HV02-16N) Nested RT-PCR HemaVision® kit for the detection of the inv16(CBFB-MYH11) inversion. Contain material for 25 tests.



Screening for 7 translocations RT-Non Nested PCR

  • HemaVision®-7 (Cat. No. HV01-7)Multiplex, RT-PCR HemaVision® kit for the screening and detection of 7 chromosomal translocations with more than 45 clinically relevant chromosomal breakpoints in just 8 hours. These 7 translocations are t(9,22) minor, major and micro; t(1,19); t(12,21); inv16, t(15,17) S, V, L; t(8,21) and t(4,11). Contain material for 25 tests (25 master reactions and 15 split-out reactions).



Screening for single translocations RT-Non Nested PCR

  • HemaVision®-1;19 (Cat. No. HV03-119) Non-nested RT-PCR HemaVision® kit for the detection of the t(1;19)(TCF3-PBX1) translocation. Contain material for 25 tests.
  • HemaVision®-4;11 (Cat. No. HV03-411) Non-nested RT-PCR HemaVision® kit for the detection of the t(4;11)(MLL-AFF1) translocation. Contain material for 25 tests.
  • HemaVision®-8;21 (Cat. No. HV03-821) Non-nested RT-PCR HemaVision® kit for the detection of the t(8;21) (RUNX1-RUNX1T1) translocation. Contain material for 25 tests.
  • HemaVision®-9;22 (Cat. No. HV03-922) Non-nested RT-PCR HemaVision® kit for the detection of the t(9;22) (BCR-ABL1) minor & major translocation. Contain material for 25 tests.
  • HemaVision®-12;21 (Cat. No. HV03-1221) Non-nested RT-PCR HemaVision® kit for the detection of the t(12;21)(ETV6-RUNX1) translocation. Contain material for 25 tests.
  • HemaVision®-15;17 (Cat. No. HV03-1517) Non-nested RT-PCR HemaVision® kit for the detection of the t(15;17) (PML-RARA) translocation. Contain material for 25 tests.
  • HemaVision®-inv16 (Cat. No. HV03-16) Non-nested RT-PCR HemaVision® kit for the detection of the inv16(CBFB-MYH11) inversion. Contain material for 25 tests.



Reagent Modules

  • HemaVision®-RM (Cat. No. HV04-RM) Reagent Module containing dNTP, Reverse Transcriptase, 5*RT-buffer and DDT for use together with the HemaVision® kits. Note: approximately 4 modules are needed for the HemaVision®-28N kit, 3 modules are needed for the HemaVision®-Screen and HemaVision®-7 kits, and 2 modules are needed for the HemaVision®-Single translocation kits.
  • HemaVision®-RMP (Cat. No. HV06-RMP) Reagent Module containing dNTP, Reverse Transcriptase, 5*RT-buffer, DDT, 10xPCR Buffer and HemaVision DNA Polymerase for use together with the HemaVision® kits. Note: approximately 4 modules are needed for the HemaVision®-28N kit, 3 modules are needed for the HemaVision®-Screen and HemaVision®-7 kits, and 2 modules are needed for the HemaVision®-Single translocation kits.



Positive Controls

  • HemaVision®-7 Positive Controls (Cat. No. HV05-7PC) Positive Controls for HemaVision®-7 and the Non- Nested Single Translocation kits. The kit contains HL60 total RNA with in vitro transcribed RNA having sequences for t(1;19), t(12;21), inv(16), t(15;17), t(9;22), t(8;21), and t(4;11). The kit contains RNA for one cDNA synthesis reaction for each of the 7 translocations.



Genomax Technologies supplies HemaVision® products in Singapore. If you have any questions, please contact This email address is being protected from spambots. You need JavaScript enabled to view it..



View HemaVision products

HemaVison® tests for screening of Leukemia-associated translocations

CE-IVD test kits for screening of Leukemia-associated translocations

HemaVision® sensitive and specific tests for detection of leukemia-associated translocations



DNA Diagnostic A/S manufactures a range of HemaVision® diagnostic kits for fast and sensitive screening of chromosome translocations associated with leukemia. The HemaVision® range of tests are fast 12 hours RT-PCR or 4 hours RT-qPCR screening tests, which can detect up to 28 translocations, enabling fast diagnostics and subsequent treatment. The starting material for the HemaVision® tests is total RNA extracted from whole blood or bone marrow. The tests can be performed as a screening for 28 translocations or 7 translocations. Single translocation tests are also available.


There are a total of 17 different kits for detection of chromosomal translocations associated with leukemia. The following CE-IVD test kits are for the screening and detection of 28 translocations in just 4 hours (-28Q), 8 hours (-Screen), or 12 hours (-28N).

  • HemaVision®-28Q
  • HemaVision®-28N
  • HemaVision®-Screen



RT-qPCR Tests for fast and sensitive screening and detection of up to 28 translocations

  • HemaVision®-28Q (Cat. No. HV01-28Q) RT-qPCR HemaVision® kit for the screening and detection of 28 chromosome translocations with more than 145 clinically relevant chromosomal breakpoints in just 4 hours. Supplied in three types of qPCR tubes: WRP, WLP or FRP. Contain material for 12 tests.
  • HemaVision®-7Q (Cat. No. HV01-7Q) RT-qPCR HemaVision® kit for the screening and detection of 7 chromosome translocations with more than 40 clinically relevant chromosomal breakpoints in just 4 hours. These 7 translocations are t(9,22) minor, major,and micro; t(1,19); t(12,21); inv16; t(15,17) S, V and L; t(8,21) and t(4,11). Supplied in tree types of qPCR tubes: WRP, WLP or CRP. Contain material for 12 tests.
  • HemaVision® Q Positive Controls (Cat. No. HV05-PCQ) Positive Controls for HemaVision®-28Q and HemaVision®-7Q . The kit contains HL-60 RNA and in vitro transcribed RNA with a translocation specific sequence. Each of the 5 tubes contains 20 µL RNA with 5x10-17 mol in vitro transcribed RNA. RNA mix contains the following translocations: t(15;17), inv(16), t(8;21), t(12;21), t(1;19), t(4;11), t(9;22), del(1), t(6;9).



Screening for 28 translocations RT-Nested PCR

  • HemaVision®-28N (Cat. No. HV01-28N) Multiplex, nested RT-PCR HemaVision® kit for the screening and detection of 28 chromosomal translocations with more than 145 clinically relevant chromosomal breakpoints in just 12 hours. Contain material for 25 tests (25 master reactions and 15 split- out reactions).
  • HemaVision®-Screen (Cat. No. HV01-Screen) The HemaVision-Screen kit is a supplementary kit to the HemaVision® -28N kit. Multiplex, nested RT-PCR HemaVision® kit for the screening of 28 chromosomal translocations with more than 145 clinically relevant chromosomal breakpoints in just 8 hours. Contain material for 25 tests. (25 master reactions).



Screening for single translocations RT-Nested PCR

  • HemaVision®-5;12N (Cat. No. HV02-512) Nested RT-PCR HemaVision® kit for the detection of the t(5;12)(ETV6-PDGFRB) translocation. Contain material for 25 tests.
  • HemaVision®-8;21N (Cat. No. HV02-821N) Nested RT-PCR HemaVision® kit for the detection of the t(8;21)(RUNX1-RUNX1T1) translocation. Contain marked material for 25 tests.
  • HemaVision®-9;22N (Cat. No. HV02-922N) Nested RT-PCR HemaVision® kit for the detection of the t(9;22)(BCR-ABL1) minor & major translocation. Contain material for 25 tests.
  • HemaVision®-15;17N (Cat. No. HV02-1517N) Nested RT-PCR HemaVision® kit for the detection of the t(15;17)(PML-RARA) translocation. Contain material for 25 tests.
  • HemaVision®-inv16N (Cat. No. HV02-16N) Nested RT-PCR HemaVision® kit for the detection of the inv16(CBFB-MYH11) inversion. Contain material for 25 tests.



Screening for 7 translocations RT-Non Nested PCR

  • HemaVision®-7 (Cat. No. HV01-7)Multiplex, RT-PCR HemaVision® kit for the screening and detection of 7 chromosomal translocations with more than 45 clinically relevant chromosomal breakpoints in just 8 hours. These 7 translocations are t(9,22) minor, major and micro; t(1,19); t(12,21); inv16, t(15,17) S, V, L; t(8,21) and t(4,11). Contain material for 25 tests (25 master reactions and 15 split-out reactions).



Screening for single translocations RT-Non Nested PCR

  • HemaVision®-1;19 (Cat. No. HV03-119) Non-nested RT-PCR HemaVision® kit for the detection of the t(1;19)(TCF3-PBX1) translocation. Contain material for 25 tests.
  • HemaVision®-4;11 (Cat. No. HV03-411) Non-nested RT-PCR HemaVision® kit for the detection of the t(4;11)(MLL-AFF1) translocation. Contain material for 25 tests.
  • HemaVision®-8;21 (Cat. No. HV03-821) Non-nested RT-PCR HemaVision® kit for the detection of the t(8;21) (RUNX1-RUNX1T1) translocation. Contain material for 25 tests.
  • HemaVision®-9;22 (Cat. No. HV03-922) Non-nested RT-PCR HemaVision® kit for the detection of the t(9;22) (BCR-ABL1) minor & major translocation. Contain material for 25 tests.
  • HemaVision®-12;21 (Cat. No. HV03-1221) Non-nested RT-PCR HemaVision® kit for the detection of the t(12;21)(ETV6-RUNX1) translocation. Contain material for 25 tests.
  • HemaVision®-15;17 (Cat. No. HV03-1517) Non-nested RT-PCR HemaVision® kit for the detection of the t(15;17) (PML-RARA) translocation. Contain material for 25 tests.
  • HemaVision®-inv16 (Cat. No. HV03-16) Non-nested RT-PCR HemaVision® kit for the detection of the inv16(CBFB-MYH11) inversion. Contain material for 25 tests.



Reagent Modules

  • HemaVision®-RM (Cat. No. HV04-RM) Reagent Module containing dNTP, Reverse Transcriptase, 5*RT-buffer and DDT for use together with the HemaVision® kits. Note: approximately 4 modules are needed for the HemaVision®-28N kit, 3 modules are needed for the HemaVision®-Screen and HemaVision®-7 kits, and 2 modules are needed for the HemaVision®-Single translocation kits.
  • HemaVision®-RMP (Cat. No. HV06-RMP) Reagent Module containing dNTP, Reverse Transcriptase, 5*RT-buffer, DDT, 10xPCR Buffer and HemaVision DNA Polymerase for use together with the HemaVision® kits. Note: approximately 4 modules are needed for the HemaVision®-28N kit, 3 modules are needed for the HemaVision®-Screen and HemaVision®-7 kits, and 2 modules are needed for the HemaVision®-Single translocation kits.



Positive Controls

  • HemaVision®-7 Positive Controls (Cat. No. HV05-7PC) Positive Controls for HemaVision®-7 and the Non- Nested Single Translocation kits. The kit contains HL60 total RNA with in vitro transcribed RNA having sequences for t(1;19), t(12;21), inv(16), t(15;17), t(9;22), t(8;21), and t(4;11). The kit contains RNA for one cDNA synthesis reaction for each of the 7 translocations.



Genomax Technologies supplies HemaVision® products in Singapore. If you have any questions, please contact This email address is being protected from spambots. You need JavaScript enabled to view it..



View HemaVision products

HemaVison® tests for screening of Leukemia-associated translocations

HemaVision-7 (HV01-7)

Screening for 7 chromosome translocations RT-Non Nested PCR

View Instructions For Use 

Contact us atTel: 65-6777 1886Fax: 65-6777 3090
Send us a messageinfo@genomax.com.sg
Visit us 237 Pandan Loop, #06-03 Westech Building, Singapore 128424